LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2018 >> Spark LT, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 24 (Engine Controls And Fuel - 1.4L (LV7) - Repair Instructions) >> Repair Instructions >> Air Cleaner Outlet Duct Replacement (L5Q) >> Installation Procedure

Installation Procedure

WARNING: This page is about a different car, the 2017 Chevrolet Spark. However, it is still accessible from the selected car via links, so may be relevant.
  1. Assemble the air cleaner outlet duct (1) with the New positive crankcase ventilation tube (3) and the New positive crankcase ventilation valve (2).
    Fig 1: Air Cleaner Outlet Duct
    GM4210136Courtesy of GENERAL MOTORS COMPANY
  2. Install the air cleaner outlet duct assembly (3) with positive crankcase ventilation tubes to the engine.
    Fig 2: Air Cleaner Outlet Duct Clamp
    GM4210134Courtesy of GENERAL MOTORS COMPANY
  3. Using EN-50956  tamper proof drive bit tighten the bolt (2) to 10 N.m (89 lb in).
  4. Position the air cleaner outlet duct (3) in place and tighten the clamp (1) on the engine.
    NOTE: Ensure the outlet duct is fully seated to the mating surfaces before clamping. Verify that the cuff is not rolled under.
  5. Connect the positive crankcase ventilation tube connector (1) to the air cleaner outlet duct. Refer to Plastic Collar Quick Connect Fitting Service .
    Fig 3: Positive Crankcase Ventilation Tube Connector
    GM4210132Courtesy of GENERAL MOTORS COMPANY
  6. Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement .