M46 Air Recirculation Door Actuator
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray Name | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | Not Required | J-35616-64B (LT BU) | No Tool Required | Not Required | Not Required | Not Required | Not Required |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | 0.35 | GN | 1614 | Recirculation Door Control | I | - |
| 2 | 0.35 | GY/RD | 598 | 5V Reference | I | - |
| 3 | - | - | - | Not Occupied | - | - |
| 4 | 0.35 | BK/YE | 1791 | Air Temperature Door Control Low Reference | I | - |
| 5 | 0.35 | YE/BK | 2274 | Recirculation Door Control | I | - |
| 6 | 0.35 0.35 |
VT/GN VT |
1838 1838 |
Recirculation Door Position Signal Recirculation Door Position Signal |
I I |
C60&MBM C60+MBM or C41+KL9+MBM or C60+MAH/MBC/KL9-MBM |