Home >> Chevrolet >> 2018 >> Spark ACTIV, Automatic CVT Trans >> Repair and Diagnosis >> Engine Mechanical >> Mechanical >> Engine Mechanical - 1.0L (L5Q) Or 1.4L (LV7) - Repair Instructions - On Vehicle >> Repair Instructions - On Vehicle >> Engine Oil Level Indicator Control Module Wiring Harness Replacement (L5Q) >> Installation Procedure

Installation Procedure

  1. GM4499155Courtesy of GENERAL MOTORS COMPANY
    CAUTION:

    Refer to Fastener Caution .

    Engine Oil Level Indicator Control Module Wiring Harness - Install and tighten to 10 N.m (89 lb in)

  2. GM4499154Courtesy of GENERAL MOTORS COMPANY

    Connect the engine oil level indicator control module wiring harness connector (1) to the engine oil level indicator control module wiring harness (2).

  3. Fig 1: Identifying Crankshaft Oil Deflector And Bolts With Tightening Sequence
    GM4499156Courtesy of GENERAL MOTORS COMPANY

    Crankshaft Oil Deflector (3) - Install

  4. Crankshaft Oil Deflector Bolt (1) [3x] Tighten in sequence to 10 N.m (89 lb in)
  5. Crankshaft Oil Deflector Bolt (2) [2x] Tighten in sequence to 25 N.m (18 lb ft)
  6. Oil Pan Replacement (L5Q)  - Install