Q8 Control Solenoid Valve Assembly X2 ( )
| - |
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray Name | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | Not Required | Not Available | No Tool Required | Not Required | Not Required | Not Required | Not Required |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| A | 0.5 0.5 |
GY BU |
- - |
Low Reference Park/Neutral Switch Signal |
I I |
M7W MHG |
| B | 0.5 0.5 |
BK GN |
- - |
Transmission Range Switch Signal P Transmission Range Switch Signal A |
I I |
M7W MHG |
| C | 0.5 0.5 |
YE GY |
- - |
Transmission Range Switch Signal C Transmission Range Switch Signal B |
I I |
M7W MHG |
| D | 0.5 0.5 |
RD YE |
- - |
Transmission Range Switch Signal B Transmission Range Switch Signal C |
I I |
M7W MHG |
| E | 0.5 0.5 |
GN RD |
- - |
Transmission Range Switch Signal A Transmission Range Switch Signal P |
I I |
M7W MHG |
| F | 0.5 0.5 |
GN BK |
- - |
Park/Neutral Switch Signal Low Reference |
I I |
M7W MHG |