Circuit/System Description
WARNING: This page is about a different variant/trim than selected.
The IAT sensor 2 produces a frequency signal, based on the inlet air temperature, which is equal to the humidity present within the sensor bore. The signal varies with inlet air temperature and is displayed by the scan tool as °C (°F) and Hertz (Hz) and the relative humidity is displayed in percent (%). The ECM supplies a regulated voltage to the signal circuit. The signal circuit is shared by the IAT sensor 2 and the humidity sensor. Ignition voltage and ground circuits are also supplied to the multifunction intake air sensor's internal circuits for these sensors:
- Humidity sensor
- IAT sensor 2
- MAF sensor
The multifunction intake air sensor houses the following:
- BARO pressure sensor
- Humidity sensor
- IAT sensor 1
- IAT sensor 2
- MAF sensor
IAT Sensor 2 - Temperature, Frequency Table
| IAT Sensor 2 | IAT Sensor 2 Frequency | IAT Sensor 2 Temperature |
|---|---|---|
| Cold | 45 Hz | -40°C (-40°F) |
| Warm | 302 Hz | 104°C (219°F) |