Dynamic Test
WARNING: This page is about a different variant/trim than selected.
- Install a 10 A fused jumper wire between the ignition terminal 1 of the Q40 Turbocharger Bypass Solenoid Valve and 12 V. Install a jumper wire between the control terminal 2 and ground.
- Verify the Q40 Turbocharger Bypass Solenoid Valve plunger retracts.
- If the plunger does not retract.
Replace the Q40 Turbocharger Bypass Solenoid Valve.
- Go to next step: If the plunger retracts.
- If the plunger does not retract.
- All OK