Component Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF, disconnect the harness connector at the appropriate Q6 Camshaft Position Actuator Solenoid Valve.
- Test for 7 - 12 Ω between the control terminal 1 or A and the low reference circuit terminal 2 or B.
- If not between 7 - 12 Ω
Replace the Q6 Camshaft Position Actuator Solenoid Valve.
- Go to next step: If between 7 - 12 Ω
- If not between 7 - 12 Ω
- Test for infinite resistance between each terminal and the Q6 Camshaft Position Actuator Solenoid Valve housing.
- If less than infinite resistance
Replace the Q6 Camshaft Position Actuator Solenoid Valve.
- Go to next step: If infinite resistance
- If less than infinite resistance
- All OK