Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF, disconnect the harness connector at the Q44 Engine Oil Pressure Control Solenoid Valve, ignition ON.
- Verify that a test lamp illuminates between the ignition circuit terminal 1 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF, remove the test lamp.
- Test for less than 2 Ω in the ignition circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF, remove the test lamp.
- Test for infinite resistance between the ignition circuit and ground
- If less than infinite resistance, repair the short to ground in the circuit.
- If infinite resistance, test all the components connected to fuse and replace as necessary.
NOTE:An short to ground in any circuit or shorted component supplied voltage by the fuse may cause the fuse to open and set a DTC.
- Go to next step: If the test lamp illuminates
- Verify that a test lamp does not illuminate between the ignition circuit terminal 1 and the control circuit terminal 2.
- If the test lamp illuminates
- Ignition OFF, disconnect the harness connector at the K20 Engine Control Module.
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K20 Engine Control Module.
- Go to next step: If the test lamp does not illuminate
- Remove the test lamp, command the Q44 Engine Oil Pressure Control Solenoid Valve On with a scan tool.
- Verify the scan tool Engine Oil Pressure Control Solenoid Valve Control Circuit High Voltage Test Status parameter displays OK.
- If OK is not displayed
- Ignition OFF, disconnect the harness connector at the K20 Engine Control Module, ignition ON.
- Test for less than 1 V between the control circuit and ground.
- If 1 V or greater, repair the short to voltage on the circuit.
- If less than 1 V, replace the K20 Engine Control Module.
- Go to next step: If OK is displayed
- Install a 3 A fused jumper wire between the control circuit terminal 2 and the ignition circuit terminal 1.
- Verify the scan tool Engine Oil Pressure Control Solenoid Valve Circuit High Voltage Test Status parameter displays Malfunction when commanding the Engine Oil Pressure Control Solenoid Valve On.
- If Malfunction is not displayed
- Ignition OFF, disconnect the harness connector at the K20 Engine Control Module.
- Test for less than 2 Ω in the control circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω replace the K20 Engine Control Module.
- Go to next step: If Malfunction is displayed
- Test or replace the Q44 Engine Oil Pressure Control Solenoid Valve.