LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2018 >> Equinox L >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 3 (Engine Mechanical - 2.0L (LTG)) >> Diagnostic Information And Procedures >> DTC P06DA-P06DC: Engine Oil Pressure Control Solenoid Valve Control >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different variant/trim than selected.
  1. Ignition OFF, disconnect the harness connector at the Q44 Engine Oil Pressure Control Solenoid Valve, ignition ON.
  2. Verify that a test lamp illuminates between the ignition circuit terminal 1 and ground.
    • If the test lamp does not illuminate and the circuit fuse is good 
    1. Ignition OFF, remove the test lamp.
    2. Test for less than 2 Ω in the ignition circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω verify the fuse is not open and there is voltage at the fuse.
    • If the test lamp does not illuminate and the circuit fuse is open 
    1. Ignition OFF, remove the test lamp.
    2. NOTE:

      An short to ground in any circuit or shorted component supplied voltage by the fuse may cause the fuse to open and set a DTC.

    3. Test for infinite resistance between the ignition circuit and ground
      • If less than infinite resistance, repair the short to ground in the circuit.
      • If infinite resistance, test all the components connected to fuse and replace as necessary.
    • Go to next step: If the test lamp illuminates 
  3. Verify that a test lamp does not illuminate between the ignition circuit terminal 1 and the control circuit terminal 2.
    • If the test lamp illuminates 
    1. Ignition OFF, disconnect the harness connector at the K20 Engine Control Module.
    2. Test for infinite resistance between the control circuit and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the K20 Engine Control Module.
    • Go to next step: If the test lamp does not illuminate 
  4. Remove the test lamp, command the Q44 Engine Oil Pressure Control Solenoid Valve On with a scan tool.
  5. Verify the scan tool Engine Oil Pressure Control Solenoid Valve Control Circuit High Voltage Test Status parameter displays OK.
    • If OK is not displayed 
    1. Ignition OFF, disconnect the harness connector at the K20 Engine Control Module, ignition ON.
    2. Test for less than 1 V between the control circuit and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V, replace the K20 Engine Control Module.
    • Go to next step: If OK is displayed 
  6. Install a 3 A fused jumper wire between the control circuit terminal 2 and the ignition circuit terminal 1.
  7. Verify the scan tool Engine Oil Pressure Control Solenoid Valve Circuit High Voltage Test Status parameter displays Malfunction when commanding the Engine Oil Pressure Control Solenoid Valve On.
    • If Malfunction is not displayed 
    1. Ignition OFF, disconnect the harness connector at the K20 Engine Control Module.
    2. Test for less than 2 Ω in the control circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω replace the K20 Engine Control Module.
    • Go to next step: If Malfunction is displayed 
  8. Test or replace the Q44 Engine Oil Pressure Control Solenoid Valve.