Control Valve Solenoid Body Wiring Harness Installation
WARNING: This page is about a different variant/trim than selected.
Control Valve Solenoid Body Wiring Harness Installation
| Callout | Component Name |
|---|---|
| 1 | Automatic Transmission Fluid Temperature Sensor Seal Procedure Install NEW seals. Do NOT reuse old seals. |
| 2 | Automatic Transmission Wiring Harness Procedure Ensure you connect all the connectors to the valve body. Tighten 8 N.m (71 lb in)
NOTE:
The bolts are captured with harness. |
| 3 | Control Valve Solenoid Body Bolt Tighten in sequence 9 N.m (80 lb in) Procedure Hand tighten and follow torque sequence below. |
| 4 | Control Valve Body Bolt (Qty: 3) Procedure Hand tighten and follow torque sequence below. |