Circuit/System Description
WARNING: This page is about a different variant/trim than selected.
| Circuit | Description |
|---|---|
| 9 V Reference | Regulated voltage supplied by the control module. |
| Signal | The control module input circuit has an internal resistance connected to ground. |
| Component | Description |
|---|---|
| Transmission Range Control Valve 2 Position Switch | A linear hall effect sensor that changes current flow based on the magnetic field's position relative to the sensor. |
| K71 Transmission Control Module | The control module contains a microprocessor used to process input data to control outputs. |
The B315B Transmission Range Control Valve 2 Position Switch monitors the position of the Mode 1 Electronic Transmission Range Selector Valve
- Default = Low Voltage
- Active = High Voltage