Exhaust Gas Recirculation Cooler Housing Installation
WARNING: This page is about a different variant/trim than selected.
- Install the NEW exhaust gas recirculation cooler housing gasket.
- Install the exhaust gas recirculation cooler housing (1).
- Install the 2 exhaust gas recirculation cooler bolts (2) and tighten to 25 N.m (18 lb ft).
- Install the 2 exhaust gas recirculation cooler bolts (3) and tighten to 25 N.m (18 lb ft).
- Install a NEW charge bypass valve vacuum hose seal (3).
- Install the charge bypass valve vacuum hose (1).
- Clip the charge bypass valve vacuum hose (1) into the retainer clip.
- Connect the charge bypass valve vacuum hose (1) to the exhaust gas recirculation vacuum regulator solenoid valve.
- Install the 2 charger bypass valve vacuum hose bracket bolts (2, 5) and tighten to 10 N.m (89 lb in).
- Install the charger bypass valve vacuum hose bracket bolt (4) and tighten to 10 N.m (89 lb in).
CAUTION:
Refer to Fastener Caution .
NOTE:
Different bolt length.
NOTE:
Different bolt length.