LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2018 >> Equinox L >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 17 (Engine Controls And Fuel - 1.6L (LH7) Diesel - Diagnostic Information And Procedures (P205B - P2BAA) And Symptoms) >> Diagnostic Information And Procedures >> Reductant System Tamper Service Bay Test >> Reductant System Tamper Warning Service Bay Test

Reductant System Tamper Warning Service Bay Test

WARNING: This page is about a different variant/trim than selected.
NOTE:
  • If the reductant level warning status is at level 4 or higher, fill the DEF tank and perform the Reductant Fluid Tank Level Reset procedure.
  • The scan tool must remain connected to the data link connector (DLC) during the entire Reductant System Tamper Warning Service Bay Test.
  • Do not perform the Reductant System Tamper Warning Service Bay Test if the diesel exhaust fluid (DEF) temperature is less than -7°C (19°F).
  1. Verify DEF tank is full and not in reductant warning level restriction.
    • If the reductant system is in restriction 

      Fill the DEF tank and perform the scan tool Reductant Fluid Tank Level Reset procedure.

    • Go to next step: If the reductant system is not in restriction 
  2. Perform the Ambient Air Temperature Reset with a scan tool if the vehicle has been driven in an outside temperature below -5°C (+23°F).
  3. Engine idling and at operating temperature, observe the DTC information with a scan tool. Verify there are no DTCs set.
    • Go to next step: If a DTC is not set 
  4. Disconnect scan tool.
  5. Ignition Off for 2 minutes.
  6. NOTE:

    Do not apply accelerator pedal after starting engine, otherwise the test will fail and will need to return to step 1 of the test.

  7. Ignition on.
  8. Connect the scan tool and select the scan tool Reductant System Tamper Warning Service Bay Test in the Output Controls menu and follow the instructions.
  9. NOTE:

    If the Reductant System Tamper Warning Service Bay Test reaches its time limit without reporting passed or failed and the Service Emission System or the Service Exhaust System message is still displayed, a second Reductant System Tamper Warning Service Bay Test will be necessary

  10. Command the Reductant System Tamper Warning Service Bay Test On with a scan tool. The Reductant System Tamper Warning Service Bay Test should start and run for up to 20 minutes.
  11. The Reductant System Tamper Warning Service Bay Test is complete when the Service Emission System message or Service Exhaust System message turns Off.
    • If the DIC message does not clear 
    1. Command a second Reductant System Tamper Warning Service Bay Test On with a scan tool.
    • If the DIC message does not clear after the second test, a condition with the system still exists.
    • Go to next step: If the DIC message clears 
  12. All OK.