Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF, disconnect the harness connector at the Q47 Exhaust Gas Recirculation Cooler Bypass Solenoid Valve. Ignition ON.
- Connect a test lamp between the control circuit terminal 2 and B+.
- Verify the test lamp turns ON and OFF while commanding the Q47 Exhaust Gas Recirculation Cooler Bypass Solenoid Valve ON and OFF with a scan tool.
- If the test lamp is always ON
- Ignition OFF, disconnect the X2 harness connector at the K20 Engine Control Module.
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground.
- If infinite resistance, replace the K20 Engine Control Module.
- If the test lamp is always OFF
- Ignition OFF, disconnect the harness connector at the K20 Engine Control Module.
- Test for less than 1 V between the control circuit and ground.
- If 1 V or greater, repair the short to voltage on the circuit.
- If less than 1 V
- Test for less than 2 Ω in the circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the K20 Engine Control Module.
- Go to next step: If the test lamp turns ON and OFF
- Ignition ON, verify a test lamp illuminates between the voltage circuit terminal 1 and ground
- If the test lamp does not illuminate
- Ignition OFF, disconnect the harness connector at the K20 Engine Control Module.
- Test for infinite resistance between the ignition circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance
- Test for less than 2 Ω in the ignition circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the K20 Engine Control Module.
- Go to next step: If the test lamp illuminates
- Test or replace the Q47 Exhaust Gas Recirculation Cooler Bypass Solenoid Valve.