Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P2227 Condition 1
The ECM detects that the BARO sensor pressure is less than 50 kPa (7.3 PSI) or greater than 115 kPa (16.7 PSI), for greater than 62.5 ms.
P2227 Condition 2
The ECM detects that the BARO sensor pressure is not within range of the calculated pressure that is derived from a system of models for greater than 5 s.
DTC P2228
The ECM detects that the BARO sensor pressure is less than 50 kPa (7.3 PSI) for greater than 5 s.
DTC P2229
The ECM detects that the BARO sensor pressure is greater than 115 kPa (16.7 PSI) for greater than 5 s.
DTC P2230