Circuit/System Verification
WARNING: This page is about a different variant/trim than selected.
- Ignition - On/Vehicle - In Service Mode
- Verify the scan tool parameter: Reductant Concentration = The value should not spike or drop out.
Perform the action while monitoring the parameter:
- Wiggle the harness and connector: A39 Reductant Tank
- Wiggle the harness and connector: K115 Reductant Control Module
- If the value spikes or drops out
Repair as necessary - Wiring/Terminal (s)/Electrical Connector (s)
- Go to next step: If the value does not spike or drop out
- Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
Verify the DTC does not set.
- If the DTC sets
Refer to: Circuit/System Testing
- Go to next step: If the DTC is not set
- If the DTC sets
- All OK.