Circuit/System Verification
WARNING: This page is about a different variant/trim than selected.
NOTE:
Circuit/System Verification requires cold start. Do not start vehicle prior to connecting scan tool and preparing to evaluate the condition during engine crank.
- Start the engine and verify that the scan tool Cylinder 1-4 Current Misfire Counters are not incrementing during first 500 engine cycles.
- If Cylinder 1-4 Current Misfire Counters are incrementing
Refer to Circuit/System Testing below.
- Go to next step: If Cylinder 1-4 Current Misfire Counters are not incrementing
- If Cylinder 1-4 Current Misfire Counters are incrementing
- Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
- Verify the DTC does not set.
- If the DTC sets
Refer to Circuit/System Testing below.
- Go to next step: If the DTC does not set
- If the DTC sets
- All OK.