Circuit/System Testing

Hazard Warning Switch Malfunction

  1. Ignition OFF, scan tool disconnected, all doors closed, all accessories OFF, disconnect the harness connector at the S26 Hazard Warning Switch. It may take up to 2 min for all vehicle systems to power down.
  2. Test for less than 5 Ω between the ground circuit terminal 1 and ground.
    • If 5 Ω or greater 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the ground circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, repair the open/high resistance in the ground connection.
    • Go to next step: If less than 5 Ω 
  3. Ignition ON.
  4. Verify the scan tool Hazard Lamps Switch parameter is Inactive.
    • If not Inactive 
    1. Ignition OFF, disconnect the X2 harness connector at the K9 Body Control Module.
    2. Test for infinite resistance between the signal circuit terminal 2 and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the K9 Body Control Module.
    • Go to next step: If Inactive 
  5. Install a 3 A fused jumper wire between the signal circuit terminal 2 and ground.
  6. Verify the scan tool Hazard Lamps Switch parameter is Active.
    • If not Active 
    1. Ignition OFF, disconnect the X2 harness connector at the K9 Body Control Module, ignition ON.
    2. Test for less than 1 V between the signal circuit terminal 2 and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V
    3. Test for less than 2 Ω in the signal circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K9 Body Control Module.
    • Go to next step: If Active 
  7. Test or replace the S26 Hazard Warning Switch.

Hazard Warning Switch Backlighting Malfunction

  1. Ignition OFF, scan tool disconnected, all doors closed, all accessories OFF, disconnect the harness connector at the S26 Hazard Warning Switch. It may take up to 2 min for all vehicle systems to power down.
  2. Test for less than 5 Ω between the ground circuit terminal 1 and ground.
    • If 5 Ω or greater 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the ground circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, repair the open/high resistance in the ground connection.
    • Go to next step: If less than 5 Ω 
  3. Connect a test lamp between the control circuit terminal 4 and ground, ignition ON.
  4. Verify the test lamp turns ON and OFF when commanding the Hazard Lamps Switch Backlight ON and OFF with a scan tool.
    • If the test lamp is always OFF 
    1. Ignition OFF, disconnect the X1 harness connector at the K9 Body Control Module.
    2. Test for infinite resistance between the control circuit and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance
    3. Test for less than 2 Ω in the control circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K9 Body Control Module.
    • If the test lamp is always ON 
    1. Ignition OFF, disconnect the X1 harness connector at the K9 Body Control Module, ignition ON.
    2. Test for less than 1 V between the control circuit terminal and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V, replace the K9 Body Control Module.
    • Go to next step: If the test lamp turns ON and OFF 
  5. Test or replace the S26 Hazard Warning Switch.