X207 Instrument Panel Harness to Instrument Panel Harness (AYF)
| - | |
Connector Part Information
|
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray Name | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | Not Required | J-35616-16 (LT GN) | No Tool Required | Not Required | Not Required | Not Required | Not Required |
| II | Not Required | J-35616-17 (LT GN) | No Tool Required | Not Required | Not Required | Not Required | Not Required |
| Pin | Size | Color | Circuit | Terminal Type ID | Option | Function | Pin | Size | Color | Circuit | Terminal Type ID | Option |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 0.35 | YE/OG | 3025 | I | AYF | Passenger IP Module Stage 1 High Control | 1 | 0.35 | YE/OG | 3025 | II | AYF |
| 2 | 0.35 | OG/WH | 3024 | I | AYF | Passenger IP Module Stage 1 Low Control | 2 | 0.35 | OG/WH | 3024 | II | AYF |
| 3 | 0.35 0.35 |
BK/WH BK/WH |
2051 2051 |
I I |
AY0/AYF AYF |
Signal Ground Signal Ground |
3 | 0.35 | BK/WH | 2051 | II | AYF |
| 4 | 0.35 | GY/OG | 3027 | I | AYF | Passenger IP Module Stage 2 High Control | 4 | - | - | - | - | - |
| 5 | 0.35 | OG/VT | 3026 | I | AYF | Passenger IP Module Stage 2 Low Control | 5 | - | - | - | - | - |