Conditions for Setting the DTC
P0030 or P0036
The engine control module detects an open in the heater circuits of the HO2S when the heater is commanded OFF for greater than 6 s.
P0031 or P0037
The engine control module detects a short to ground in the heater output low side driver circuit of the heated oxygen sensor when the heater is commanded OFF for greater than 6 s.
P0032 or P0038
The engine control module detects a short to voltage in the heater output low side driver circuit of the heated oxygen sensor when the heater is commanded ON for greater than 6 s.
P0053 or P0054
The ECM detects the HO2S heater is not within a specified resistance range at engine start-up.
P0135 or P0141
The ECM detects that the HO2S heater current is greater than 2.5 A or less than 0.3 A for greater than 10 s.