Home >> Chevrolet >> 2017 >> Spark LT, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 62 (Automatic Transmission Cooling System) >> Repair Instructions >> Transmission Fluid Cooler Hose/Pipe Quick-Connect Fitting Disconnection and Connection >> Installation Procedure

Installation Procedure

WARNING: This page is about a different car, the 2019 Buick Cascada, 2018 Buick Cascada, and 2017 Buick Cascada. However, it is still accessible from the selected car via links, so may be relevant.
    NOTE:
    • Do not reuse any of the existing oil lines or oil line fittings if there is excessive corrosion.
    • Do not reuse any of the existing retaining rings that were removed from the existing quick connect fittings. Install new retaining rings.
    • Ensure the following procedures are performed when installing the new retaining rings onto the fittings.
  1. Install a new retaining ring into the quick connect fitting using the following procedure:
    1. GM2027468

      Hook one of the open ends of the retaining ring (1) in one of the slots in the quick connect fitting.

    2. GM2027469

      Rotate the retaining ring (1) around the fitting until the retaining ring is positioned with all three ears through the three slots on the fitting.

    3. GM2027470

      Do not install the new retaining ring (1) onto the fitting by pushing the retaining ring.

    4. GM2027473

      Ensure that the three retaining ring ears are seen from inside the fitting (1) and that the retaining ring moves freely in the fitting slots.

  2. GM2027475

    Install the cooler line (1) into the quick connect fitting (2).

  3. Insert the cooler line end into the quick connect fitting until a click is either heard or felt.
  4. GM2027476

    Do not use the plastic cap (1) on the cooler line in order to install the cooler line into the fitting.

  5. Pull back sharply on the cooler line in order to ensure that the cooler line is fastened into the quick connect fitting.
  6. GM2027482
    NOTE:

    Do not manually depress the retaining clip when installing the plastic cap.

    Position (snap) the plastic cap (1) onto the fitting. Do not manually depress the retaining ring when installing the plastic cap onto the quick connect fitting.

  7. Ensure that the plastic cap is fully seated against the fitting.
  8. GM2027484

    Ensure that no gap is present between the plastic cap (1) and the fitting (2).

  9. GM2027485

    Ensure that the yellow identification band (1) on the tube is hidden within the quick connect fitting.

  10. GM2027486

    A hidden yellow identification band (1) indicates proper joint seating.