LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2017 >> Spark LT, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 51 (Folding Top) >> Diagnostic Information and Procedures >> DTC B36A3 >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2019 Buick Cascada, 2018 Buick Cascada, and 2017 Buick Cascada. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF, disconnect inline harness connector X431. it may take up to 2 min for all vehicle systems to power down.
    NOTE:

    All testing is done at the K23 Folding Top Control Module harness side of the connector.

  2. Test for less than 10 Ω between the low reference circuit terminal 1 and ground.
    • If 10 Ω or greater 
    1. Ignition OFF, disconnect the harness connector at the K23 Folding Top Control Module.
    2. Test for less than 2 Ω in the low reference circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K23 Folding Top Control Module.
    • Go to next step: If less than 10 Ω 
  3. Ignition ON.
  4. Test for 4.8 - 5.2 V between the 5 V reference circuit terminal 5 and ground.
    • If less than 4.8 V 
    1. Ignition OFF, disconnect the harness connector at the K23 Folding Top Control Module.
    2. Test for infinite resistance between the 5 V reference circuit and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • Go to next step: If infinite resistance
    3. Test for less than 2 Ω in the 5 V reference circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K23 Folding Top Control Module.
    • If greater than 5.2 V 
    1. Ignition OFF, disconnect the harness connector at the K23 Folding Top Control Module, ignition ON.
    2. Test for less than 1 V between the 5 V reference circuit and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V, replace the K23 Folding Top Control Module.
    • Go to next step: If between 4.8 - 5.2 V 
  5. Verify the scan tool B242 Folding Top Stowage Compartment Flaps Enable Sensor parameter equals 0 V.
    • If not equal 0 V 
    1. Disconnect the harness connector at the K23 Folding Top Control Module.
    2. Test for less than 1 V between the signal circuit and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V replace the K23 Folding Top Control Module
    • Go to next step: If equal to 0 V 
  6. Install a 3 A fused jumper wire between the signal circuit terminal 6 and 5 V reference circuit terminal 5.
  7. Verify the scan tool B242 Folding Top Stowage Compartment Flaps Enable Sensor parameter is greater than 4.8 V.
    • If less than 4.8 V 
    1. Disconnect the harness connector at the K23 Folding Top Control Module.
    2. Test for infinite resistance between the signal circuit terminal and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • Go to next step: If infinite resistance,
    3. Test for less than 2 Ω in signal circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K23 Folding Top Control Module.
    • Go to next step: If greater than 4.8 V 
  8. Replace the B242 Folding Top Stowage Compartment Flap Enable Sensor.