LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2017 >> Spark LT, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 38 (HVAC System - Automatic) >> Diagnostic Information and Procedures >> DTC B3843 >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2019 Buick Cascada, 2018 Buick Cascada, and 2017 Buick Cascada. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF and all vehicle systems OFF, disconnect the harness connector at the B108 Air Quality Sensor. It may take up to 2 min for all vehicle systems to power down.
  2. Test for less than 10 Ω between the ground circuit terminal 2 and ground.
    • If 10 Ω or greater 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the ground circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, repair the open/high resistance in the ground connection.
    • Go to next step: If less than 10 Ω 
  3. Ignition ON.
  4. Verify a test lamp illuminates between the ignition circuit terminal 1 and ground.
    • If the test lamp does not illuminate and the circuit fuse is good 
    1. Ignition OFF, remove the test lamp.
    2. Test for less than 2 Ω in the ignition circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, verify the fuse is OK and there is voltage at the fuse.
    • If the test lamp does not illuminate and the circuit fuse is open 
    1. Ignition OFF, remove the test lamp.
    2. Test for infinite resistance between the ignition circuit and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the B108 Air Quality Sensor.
    • Go to next step: If the test lamp illuminates 
  5. Verify a test lamp does not illuminate between the signal circuit terminal 3 and ground.
    • If the test lamp illuminates 
    1. Ignition OFF, remove the test lamp and disconnect the harness connector at the K33 HVAC Control Module. Ignition ON.
    2. Test for less than 1 V between the signal circuit and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V, replace the K33 HVAC Control Module.
    • Go to next step: If the test lamp does not illuminate 
  6. Test for greater than 10 V between the signal circuit and ground.
    • If less than 10 V 
    1. Ignition OFF, disconnect the harness connector at the K33 HVAC Control Module.
    2. Test for infinite resistance between the signal circuit and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • Go to next step: If infinite resistance
    3. Test for less than 2 Ω in the signal circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K33 HVAC Control Module.
    • Go to next step: If greater than 10 V 
  7. Replace the B108 Air Quality Sensor.