Circuit/System Testing
WARNING: This page is about a different car, the 2019 Buick Cascada, 2018 Buick Cascada, and 2017 Buick Cascada. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition OFF and all vehicle systems OFF, disconnect the harness connector at the B108 Air Quality Sensor. It may take up to 2 min for all vehicle systems to power down.
- Test for less than 10 Ω between the ground circuit terminal 2 and ground.
- If 10 Ω or greater
- Ignition OFF.
- Test for less than 2 Ω in the ground circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, repair the open/high resistance in the ground connection.
- Go to next step: If less than 10 Ω
- Ignition ON.
- Verify a test lamp illuminates between the ignition circuit terminal 1 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF, remove the test lamp.
- Test for less than 2 Ω in the ignition circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, verify the fuse is OK and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF, remove the test lamp.
- Test for infinite resistance between the ignition circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the B108 Air Quality Sensor.
- Go to next step: If the test lamp illuminates
- Verify a test lamp does not illuminate between the signal circuit terminal 3 and ground.
- If the test lamp illuminates
- Ignition OFF, remove the test lamp and disconnect the harness connector at the K33 HVAC Control Module. Ignition ON.
- Test for less than 1 V between the signal circuit and ground.
- If 1 V or greater, repair the short to voltage on the circuit.
- If less than 1 V, replace the K33 HVAC Control Module.
- Go to next step: If the test lamp does not illuminate
- Test for greater than 10 V between the signal circuit and ground.
- If less than 10 V
- Ignition OFF, disconnect the harness connector at the K33 HVAC Control Module.
- Test for infinite resistance between the signal circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- Go to next step: If infinite resistance
- Test for less than 2 Ω in the signal circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the K33 HVAC Control Module.
- Go to next step: If greater than 10 V
- Replace the B108 Air Quality Sensor.