LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2017 >> Spark LT, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 24 (Wiring Systems And Power Management - Repair Instructions) >> Repair Instructions >> Tyco/AMP Connectors (102-Way Inline) >> Terminal Removal Procedure

Terminal Removal Procedure

WARNING: This page is about a different car, the 2019 Buick Cascada, 2018 Buick Cascada, and 2017 Buick Cascada. However, it is still accessible from the selected car via links, so may be relevant.
GM2146431

View of a typical connector in the assembled position.

  1. GM2146432

    Pull the locking lever to the 90 degree position from the connector body.

  2. GM2146434

    With the locking lever in the 90 degree position and the male connector body separated, it can be slid outward for removal.

  3. GM2146435

    Slide the male connector body out away from the guide plates.

  4. GM2146438
    NOTE:

    During assembly the terminal position assurance (TPA) will not fully seat if any terminal is not fully seated.

    Using terminal release tool J-38125-11A or equivalent, remove the TPA from the connector body.

  5. GM2146439

    Using terminal release tool J-38125-566, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.

  6. GM2146440

    Using terminal release tool J-38125-560, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.

  7. GM2146442

    Using terminal release tool J-38125-221, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.

  8. GM2146443

    The female connector body may have an additional connector hooked to the edge of the body. Use terminal release tool J-38125-11A or equivalent to release the locking tab and slide the connector off the female body.

  9. GM2146444

    Move the locking lever 180 degrees from the connected position.

  10. GM2146445

    With the locking lever in the 180 degree position the guide plates can be removed from the connector body.

  11. GM2146446
    NOTE:

    During assembly the TPA will not fully seat if any terminal is not fully seated.

    Using terminal release tool J-38125-11A or equivalent, remove the TPA from the connector body.

  12. GM2146447

    Using terminal release tool J-38125-216, lift the terminal plate past the terminals and out of the connector body cavity.

  13. GM2146449

    Terminal plate will bind slightly on each corner.

  14. GM2146451

    Using terminal release tool J-38125-221, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.

  15. GM2146452

    Using terminal release tool J-38125-212, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.

  16. GM2146453

    Using terminal release tool J-38125-560, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.

  17. GM2146449

    Press the terminal plate back into the female connector to the preset position. The plate will bind slightly on each corner.

  18. GM2146454

    With the locking lever in the 180 degree position, align the guide plates to mesh with the gears on the locking lever.

  19. GM2146435

    Slide the male connector body back inward toward the guide plates.

  20. GM2146434

    With the locking lever in the 90 degree position and the male connector body connected, it can be slid inward for assembly.

  21. GM2146431

    Move the lever into the locked position or in the assembled position. This will pull the male connector down into the female connector.

  22. Repair the terminal by following the Repairing Connector Terminals (Terminated Lead Repair)  procedure.
  23. Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies.