Terminal Removal Procedure

WARNING: This page is about a different car, the 2019 Buick Cascada, 2018 Buick Cascada, and 2017 Buick Cascada. However, it is still accessible from the selected car via links, so may be relevant.

Follow the steps below in order to remove terminals from the connector.

  1. GM1709308

    Locate the lever lock on the wire dress cover. Remove the connector position assurance (CPA) and slide the lever lock away from the connector body.

  2. Disconnect the connector from the component.
  3. GM1709309

    Locate the dress cover locking tabs on the dress cover of the connector. Using a small flat-blade tool release all of the locking tabs.

  4. GM1709311

    Release the lower wire dress cover locking tab.

  5. GM1709312

    Release the upper wire dress cover locking tab.

  6. Once the locks are unlocked, lift the dress cover off.
  7. GM1709313
    NOTE:

    Always use care when removing a terminal position assurance (TPA) in order to avoid damaging it.

    Remove the TPA by inserting a small flat-blade tool into the locking tabs on both sides of the TPA . Gently pry the TPA out of the connector.

  8. GM1709314

    Remove the nose piece by inserting a small flat-blade tool into the locking tabs on both sides of the nose piece. Gently pry the nose piece out of the connector.

  9. GM1709315

    Insert the J-38125-12A tool to release the terminals by inserting the tool into the terminal release cavity.

  10. GM1709316

    While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.

  11. Repair the terminal by following the Repairing Connector Terminals (Terminated Lead Repair)  procedure.
  12. Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies.