LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2017 >> Malibu LS >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 3 (Hybrid/EV System Heating And Cooling) >> Diagnostic Information and Procedures >> DTC P0A9C-P0A9F, P0AC6-P0AC9, P0ACB-P0ACE, P0AE9-P0AEC, P0BC3-P0BC6, P0C34-P0C37, P0C7D-P0C80, P0C82-P0C85, P0C89, P0C8A-P0C8C, P0C8E-P0C91, P0C93-P0C96, P0C98-P0C9B, P0CA9-P0CAC, P0CAE-P0CB1, P0CB3-P0CB6 or P0CB8-P0CBB: Hybrid/EV Battery Temperature Sensor >> Circuit/System Verification

Circuit/System Verification

WARNING: This page is about a different variant/trim than selected.
  1. Vehicle ON.
  2. Verify the scan tool Hybrid/EV Powertrain Control Module 2 Battery 1 - 16 temperature parameters are all between -69 and +160°C (-92 and + 320°F) with less than a 25°C (45°F) difference between any of the temperature sensor readings.
    • If not within the specified range 

      Refer to Circuit/System Testing.

    • If within the specified range 
  3. All OK.