Home >> Chevrolet >> 2017 >> Malibu LS >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 3 (Hybrid/EV System Heating And Cooling) >> Diagnostic Information and Procedures >> DTC P0A85, P0BC8-P0BCA or P0D64-P0D66: Hybrid/EV Battery Pack Cooling Fan >> Conditions for Setting the DTC

Conditions for Setting the DTC

WARNING: This page is about a different variant/trim than selected.

P0A85 

A short to voltage is detected when the hybrid/EV battery pack cooling fan speed control circuit voltage is greater than 9V.

P0BC8 

The difference between the commanded hybrid/EV battery pack cooling fan speed and the hybrid/EV battery pack cooling fan speed feedback signal is too great during a 43 second test period.

P0BC9 

The hybrid/EV battery pack cooling fan speed feedback signal is less than 8 Hz.

P0BCA 

The hybrid/EV battery pack cooling fan speed feedback signal is greater than 290 Hz.

P0D64 

An open is detected when the hybrid/EV battery pack cooling fan enable control circuit voltage is between 1.14 and 2.81 volts.

P0D65 

A short to ground is detected when the hybrid/EV battery pack cooling fan enable control circuit voltage is less than 5.35V.

P0D66 

A short to voltage is detected when the hybrid/EV battery pack cooling fan enable control circuit voltage is greater than 5.27V.