Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
P145C Pump Stuck Off
- Vehicle in Service Mode.
- Verify the scan tool EVAP Leak Detection Pump Pressure parameter.
- Command the EVAP Leak Detection Pump ON with a scan tool
- The EVAP Leak Detection Pump Pressure should decrease greater than 1.5 kPa (0.21 PSI) from step 2.
- If not within specified range
Replace the Q63 Evaporative Emission System Leak Detection Pump Assembly
- If within specified range
- If not within specified range
- All OK
P145D Pump Stuck On
- Vehicle in Service Mode.
- Verify the scan tool EVAP Leak Detection Pump Pressure parameter.
- Command the EVAP Leak Detection Pump Switching Valve Command to Not Venting position with a scan tool
- The EVAP Leak Detection Pump Pressure should not change from step 2 (within 0.2 kPa / 0.029 PSI).
- If not within specified range
Replace the Q63 Evaporative Emission System Leak Detection Pump Assembly
- If within specified range
- If not within specified range
- All OK