Turbocharger Bypass Valve Solenoid Replacement
WARNING: This page is about a different variant/trim than selected.
| Callout | Component Name |
|---|---|
| Preliminary Procedure Air Cleaner Outlet Duct Replacement |
|
| 1 | Electrical Connector Procedure Disconnect the electrical connector. |
| 2 | Turbocharger Bypass Valve Solenoid Bolt [3x]
CAUTION:
Refer to Fastener Caution
. Tighten 8 N.m (71 lb in) |
| 3 | Turbocharger Bypass Valve Solenoid |
| 4 | Turbocharger Bypass Valve Solenoid Seal Procedure Inspect the turbocharger bypass valve solenoid seal and replace as necessary. |