Static Test
WARNING: This page is about a different variant/trim than selected.
- Ignition/Vehicle - Off
- Disconnect the appropriate electrical connector: Q6 Camshaft Position Actuator Solenoid Valve
- Test for 5 to 12 Ω between the test points: Control terminal 1/A & Low Reference terminal 2/B
- If not between 5 and 12 Ω
Replace the component: Q6 Camshaft Position Actuator Solenoid Valve
- If between 5 and 12 Ω
- If not between 5 and 12 Ω
- Test for infinite resistance between the test points: Each terminal of the component & The component's housing
- If less than infinite resistance
Replace the component: Q6 Camshaft Position Actuator Solenoid Valve
- If infinite resistance
- If less than infinite resistance
- All OK.