Dynamic Test
WARNING: This page is about a different variant/trim than selected.
- Ignition/Vehicle - Off
- Disconnect the appropriate electrical connector: Q6 Camshaft Position Actuator Solenoid Valve
- Connect a jumper wire between the test points: Low Reference terminal 2/B & Ground
- Momentarily connect a 7.5 A fused jumper wire between the test points: Control terminal 1/A & B+
Verify the component turns On and Off when connecting and disconnecting the jumper wire: Q6 Camshaft Position Actuator Solenoid Valve
- If the component does not turn On and Off
Replace the component: Q6 Camshaft Position Actuator Solenoid Valve
- If the component turns On and Off
- If the component does not turn On and Off
- All OK.