Circuit/System Verification
- Ignition ON.
- Verify the scan tool Fuel Level Sensor parameter is between 0.5 - 3.5 V and varies with fuel level.
- If not between 0.5 - 3.5 V or does not vary with fuel level
Refer to Circuit/System Testing
- If between 0.5 - 3.5 V and varies with fuel level
- If not between 0.5 - 3.5 V or does not vary with fuel level
- Verify the fuel level gauge sweeps when performing the scan tool Instrument Cluster Gauge Sweep control function.
- If the fuel level gauge does not sweep
Replace the P16 Instrument Cluster
- If the level gauge sweeps
- If the fuel level gauge does not sweep
- All OK.