LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2015 >> Spark EV >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Component Locations - Electrical Center Identification Views >> Electrical Center Identification Views >> X50A Fuse Block - Underhood X3

X50A Fuse Block - Underhood X3

GM2220560
Connector Part Information
  • Harness Type: Engine
  • OEM Connector: 13732282
  • Service Connector: 13505902
  • Description: 50-Way F DSQ 1.5 2.8 Metri Pack 800 Series (BK)
Terminal Part Information

Terminal Type ID Terminated Lead Diagnostic Test Probe Terminal Removal Tool Service Terminal Tray Core Crimp Insulation Crimp
I 13327182 J-35616-64B (L-BU) J-38125-215A Not Available Not Available E A
II 13327116 J-35616-64B (L-BU) J-38125-215A Not Available Not Available E A
III 13327116 J-35616-64B (L-BU) J-38125-215A Not Available Not Available F G
Pin Size Color Circuit Function Terminal Type ID Option
1 0.5 BN/WH 419 Check Engine Indicator Control I -
2 0.5 GN/GY 333 Brake Fluid Level Sensor Signal I -
3 - - - Not Occupied - -
4 0.75 VT/WH 239 Run/Crank Ignition 1 Voltage II -
5 0.5 RD/BN 1742 Battery Positive Voltage II -
6-11 - - - Not Occupied - -
12 0.5 BK 350 Ground II -
13-18 - - - Not Occupied - -
19 0.5 VT/BK 339 Run/Crank Ignition 1 Voltage II -
20 - - - Not Occupied - -
21 0.5 GY 139 Run/Crank Ignition 1 Voltage II -
22 - - - Not Occupied - -
23 4 RD/WH 140 Battery Positive Voltage III -
24-27 - - - Not Occupied - -
28 2.5 RD/GN 40 Battery Positive Voltage III -
29 3 RD/WH 640 Battery Positive Voltage III -
30 0.5 VT/BN 300 Run Ignition 3 Voltage II -
31 0.5 RD/WH 2740 Battery Positive Voltage II -
32 0.5 VT/GN 39 Run/Crank Ignition 1 Voltage II -
33 0.5 RD/WH 3440 Battery Positive Voltage II -
34 0.5 RD/GY 2140 Battery Positive Voltage II -
35 0.5 RD/BN 2940 Battery Positive Voltage II CBT
36 0.5 RD/YE 240 Battery Positive Voltage II -
37 0.5 RD/VT 3340 Battery Positive Voltage II -
38-46 - - - Not Occupied - -
47 0.75 RD/BU 840 Battery Positive Voltage II -
48 0.75 RD/VT 340 Battery Positive Voltage II -
49-50 - - - Not Occupied - -