Installation Procedure
- Connect the actuator rod (3) to the detent lever assembly.
- Install the manual shaft detent (with shift position switch) lever assembly (4).
- Install the manual shaft (2).
- Install the manual shaft detent lever hub pin (1) to height of 7.9 mm (0.38 in) (b).
- Install the NEW manual shift shaft pin (5) using DT-41229
pin installer. Use a NEW pin to ensure proper engagement with the case.CAUTION: Use J 41229 to install the manual shaft pin at the correct height in order to properly secure the manual shaft. If you install the pin too deep, the case bore may crack.
- Inspect pin installed height is within 7.2-8.2 mm (0.28-0.32 in) (a).
- Install the control valve body. Refer to Control Valve Body Replacement .
- After repairs, refer to Control Module References for programming and set up procedures.