LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2015 >> Cruze LT, Automatic Trans >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission - 6T30 (MH9) Or 6T40 (MH8) - Repair Instructions - Off Vehicle >> Repair Instructions - Off Vehicle >> Torque Converter Housing with Fluid Pump Assembly Installation (6T40/6T45/6T50 Non Hybrid)

Torque Converter Housing with Fluid Pump Assembly Installation (6T40/6T45/6T50 Non Hybrid)

Fig 1: Identifying Torque Converter Housing & Fluid Pump Assembly
GM1891439Courtesy of GENERAL MOTORS COMPANY
Callout Component Name
1 Fluid Pump Seal Assembly
2 Torque Converter Housing Gasket
3 Torque Converter (w/Fluid Pump) Housing Assembly
NOTE: Rotate the differential slightly in each direction using the rotating tool to align the Differential Pinion Gears with the Differential Ring Gear in the Torque Converter Housing.
  • DT-47793  Differential Rotating Tool for 6T40/45 applications
  • DT-49938  Differential Rotating Tool for 6T50 applications

Special Tools

  • DT-47793  Differential Rotating Tool
  • DT-49938  Differential Rotating Tool

For equivalent regional tools, refer to Special Tools .
4 Torque Converter and Differential Housing Bolts M8 x 30 (Qty: 15)
CAUTION: Refer to Fastener Caution .

Procedure 
Tighten the bolts in sequence shown.
Tighten 
10 N.m (89 lb in) then rotate the bolt an additional 50 degrees
Special Tool 
EN-45059  Angle Meter or equivalent
For equivalent regional tools, refer to Special Tools .