Conditions for Running the DTC
P182E
- DTC P0101, P0102, P0103, P0106, P0107, P0108, P0171, P0172, P0174, P0175, P0201, P0202, P0203, P0204, P0205, P0206, P0207, P0208, P0300, P0301, P0302, P0303, P0304, P0305, P0306, P0307, P0308, P0401, P042E, P0722 or P0723 is not set.
- Engine speed is 400-7, 500 RPM for 5 s.
- Ignition voltage is 9-32 V.
- Engine torque signal is valid.
- DTC runs continuously when the above conditions are met.
P1915
- DTC P0722, P0723 or P1915 is not set.
- Transmission output shaft speed is 90 RPM or less.
- Ignition voltage is 6-32 V.
- DTC runs when conditions above are met during engine start sequence.