Conditions for Setting the DTC
Condition 1
TCM has detected an internal temperature condition of 144°C (291°F) or greater for 5 s.
Condition 2
Ignition voltage is 18 V or greater and the TCM temperature is 50°C (122°F) or greater for 2 s.
Condition 1
TCM has detected an internal temperature condition of 144°C (291°F) or greater for 5 s.
Condition 2
Ignition voltage is 18 V or greater and the TCM temperature is 50°C (122°F) or greater for 2 s.