Repair Instructions: Flushing: Notes
Special Tools
- BO-42220 Universal 12V Leak Detection Lamp
- GE-41447 R-134A A/C Tracer Dye Box of 24
- GE-45268 A/C Flush Adapter Kit
For equivalent regional tools, refer to Special Tools .
NOTE:
Flushing with the ACR 2000 is not intended to remove metal from the A/C system.
Flushing is intended to remove the following:
- Contaminated polyalkylene glycol (PAG) oil
- Desiccant, following a desiccant bag failure
- Overcharge of PAG oil
- Refrigerant contamination