Noise Diagnosis - Blower Motor
| Step | Action | Yes | No |
|---|---|---|---|
| DEFINITION: Noise originating from the blower motor. | |||
| 1 | Were you sent here from Symptoms or another diagnostic table? | Go to Step 2 | Go to Symptoms - HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic |
| 2 | Inspect the air inlet grille for debris. Is debris present? |
Go to Step 8 | Go to Step 3 |
| 3 |
|
Go to Step 4 | Go to Step 11 |
| 4 | Inspect for excessive vibration at each blower motor speed by feeling the blower case. Is excess vibration present? |
Go to Step 6 | Go to Step 5 |
| 5 | Listen to the blower motor at each speed. Is the blower motor making a squeaking or chirping noise? |
Go to Step 9 | Go to Step 11 |
| 6 |
|
Go to Step 8 | Go to Step 7 |
| 7 | Inspect the blower motor for the following conditions:
Did you find any of these conditions? |
Go to Step 9 | Go to Step 10 |
| 8 | Remove the foreign material. Is the action complete? |
Go to Step 10 | - |
| 9 | Replace the blower motor. Refer to Blower Motor Replacement . Is the repair complete? |
Go to Step 11 | - |
| 10 | Install the blower motor. Refer to Blower Motor Replacement . Is the action complete? |
Go to Step 11 | - |
| 11 | Operate the system in order to verify the repair. Did you find and correct the condition? |
System OK | Go to Step 2 |