Defrosting Insufficient (without Y8X)
| Step | Action | Yes | No |
|---|---|---|---|
| DEFINITION: Time required to defrost the windshield is longer than normal. | |||
| 1 | Were you sent here from Symptoms or another diagnostic table? | Go to Step 2 | Go to Symptoms - HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic |
| 2 |
|
Go to Step 3 | Go to Step 8 |
| 3 | Measure the engine operating temperature. Does engine reach a normal operating temperature? |
Go to Step 4 | Go to Step 6 |
| 4 |
|
Go to Step 9 | Go to Step 5 |
| 5 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test . Is the A/C system operating within the specifications? |
Go to Step 7 | Go to Step 10 |
| 6 | Repair the low engine temperature concern. Refer to Engine Fails To Reach Normal Operating Temperature
. Is the repair complete? |
Go to Step 12 | - |
| 7 | Inspect for correct operation of the air inlet valve. Is the air inlet valve operating correctly? |
Go to Step 12 | Go to Step 11 |
| 8 | Repair the air delivery concern. Refer to Symptoms - HVAC Systems - Manual
. Is the repair complete? |
Go to Step 12 | - |
| 9 | Repair the heating concern. Refer to Heating Performance Diagnostic . Is the repair complete? |
Go to Step 12 | - |
| 10 | Repair the A/C performance concern. Refer to Symptoms - HVAC Systems - Manual
or Symptoms - HVAC Systems - Automatic
. Is the repair complete? |
Go to Step 12 | - |
| 11 | Repair the air inlet valve concern. Refer to Symptoms - HVAC Systems - Manual
. Is the repair complete? |
Go to Step 12 | - |
| 12 | Operate the system in order to verify the repair. Did you find and correct the problem? |
System OK | Go to Step 2 |