Conditions for Setting the DTC
B023A 02
The stepper motors supply output is shorted to ground.
B0223 01, B0233 01 or B0408 01
At least one control circuits of the appropriate stepper motor is shorted to voltage when motor starts moving. Faults are not detected when motor is already running or target position is already reached.
B0223 06, B0233 06 or B0408 06
At least one control circuits of the appropriate stepper motor is shorted to ground or open when motor starts moving. Faults are not detected when motor is already running or target position is already reached.