Dynamic Test
WARNING: This page is about a different variant/trim than selected.
- Install a 10 A fused jumper wire between the ignition terminal 1 and 12 V. Install a jumper wire between the control terminal 2 and ground.
- Verify the Q47 Exhaust Gas Recirculation Cooler Bypass Solenoid Valve clicks.
- If the Q47 Exhaust Gas Recirculation Cooler Bypass Solenoid Valve does not click
Replace the Q47 Exhaust Gas Recirculation Cooler Bypass Solenoid Valve.
- If the Q47 Exhaust Gas Recirculation Cooler Bypass Solenoid Valve clicks
- If the Q47 Exhaust Gas Recirculation Cooler Bypass Solenoid Valve does not click
- All OK