Conditions for Running the DTCs
WARNING: This page is about a different variant/trim than selected.
P214F or P21DD
- DTC P205C, P20B9, P20BB, P20BC or P20C0 is not set.
- Reductant tank heater is commanded On for greater than 50 s.
- Battery voltage is greater than 11 V for at least 3 s.
- The engine is off for greater than 5 minutes.
- Engine speed is greater than 600 RPM for at least 10 s.
- Reductant level is not in restriction or empty level state.
- Initial reductant tank temperature is less than 42°C (108°F).
- The DTCs run once per key cycle after the above conditions are met.
P221C or P221D
- The reductant line heater is commanded On.
- Battery voltage is greater than 11 V for at least 3 s.
- The engine is Off for greater than 5 minutes.
- Engine speed is greater than 600 RPM for at least 10 s.
- Reductant level is not in restriction or empty level state.
- The DTCs run once per key cycle after the above conditions are met.
P221E or P221F
- The reductant pump heater is commanded On.
- Battery voltage is greater than 11 V for at least 3 s.
- The engine has been Off for greater than 5 minutes.
- Engine speed is greater than 600 RPM for at least 10 s.
- Reductant level is not in restriction or empty level state.
- The DTCs run continuously once the above conditions are met.