EN 46091-1 Pressure Regulator Adjustment
WARNING: This page is about a different variant/trim than selected.
NOTE:
Some EN-46091-1 regulators may have the adjusting knob riveted in place. The rivet head must be drilled out with a 5/16 inch drill bit before adjustment. Do not drill more than 1/8 inch in depth or just enough to remove the rivet head. The rivet shaft does not have to be removed from the regulator.
- Connect the EN-47603 to the EN-46091-1 gauge set outlet and connect shop air to the EN-47603 .
- Open the shutoff valve, then slowly adjust the regulator on the EN-46091-1 until the gauge reads 55 kPa (8 psi).
- Close the air supply valve and remove the EN-47603 from the gauge assembly.
- The gauge set is now calibrated to perform the test.