Component Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF, disconnect the harness connector at the Q13 Evaporative Emission Vent Solenoid Valve.
- Test for 10-30 Ω between the control terminal B or 1 and the B+ circuit terminal A or 2.
- If not between 10-30 Ω
Replace the Q13 Evaporative Emission Vent Solenoid Valve.
- If between 10-30 Ω
- If not between 10-30 Ω
- All OK.