Circuit/System Verification
WARNING: This page is about a different variant/trim than selected.
NOTE:
An audible click may be heard when performing step 2 below.
- Ignition ON.
- Command the EVAP Vent Solenoid Valve to ON (Not Venting) and OFF (Venting) with a scan tool while observing the following control circuit status parameters:
- EVAP Vent Solenoid Valve Control Circuit Open Test Status
- EVAP Vent Solenoid Valve Control Circuit Low Voltage Test Status
- EVAP Vent Solenoid Valve Control Circuit High Voltage Test Status
- If Malfunction is displayed
Refer to Circuit/System Testing
- If Malfunction is not displayed
- Verify the EVAP Vent Solenoid Valve control circuit parameters above do not display Malfunction when moving the related harnesses and connectors of the Q13 Evaporative Emission Vent Solenoid Valve.
- If Malfunction is displayed
Refer to Circuit/System Testing
- If Malfunction is not displayed
- If Malfunction is displayed
- Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
- Verify the DTC does not set.
- If the DTC sets
Refer to Circuit/System Testing
- If the DTC does not set
- If the DTC sets
- All OK.