Repair Verification
WARNING: This page is about a different variant/trim than selected.
- Install any components or connectors that have been removed or replaced during diagnosis.
- Perform any adjustment, programming or setup procedures that are required when a component or module is removed or replaced.
- Clear the DTCs.
- Ignition Off, all vehicle systems Off, this may take up to 2 minutes.
- Ignition On, command the Reductant System Leak Test On with a scan tool. Allow the pressure to build for at least 2 minutes. The first 60 s, the system performs a system purge. Observe the scan tool Reductant Pressure sensor parameter. The reading should be between 400-650 kPa (58-94 psi) and there should be no leaks in the system.NOTE:
- The diesel exhaust fluid (DEF) and ambient air temperatures must be greater than -7°C (+19°F) before proceeding with this procedure.
- Exhaust Gas Temperature (EGT) sensor 2 must be less than 200°C (392°F) prior to running the Reductant System Leak Test.
- If a leak is found
Repair as necessary.
- If no leak is found
- Ignition Off, all vehicle systems Off, this may take up to 2 minutes.
- Engine idling for 30 s.
- Ignition Off, all vehicle systems Off, this may take up to 2 minutes.
- Ignition On, verify the DTC does not set.
- If the DTC sets
A condition with the system still exists.
- If the DTC does not set
- If the DTC sets
- All OK.