Circuit/System Verification
WARNING: This page is about a different variant/trim than selected.
- Ignition On.
- Command the Reductant Purge Valve On and Off with a scan tool. You should hear an audible click
- If an audible click is not heard
Refer to Circuit/System Testing.
- If an audible click is heard
- If an audible click is not heard
- Command the Reductant Purge Valve On and Off with a scan tool while observing the Reductant Purge Solenoid Valve Control Circuit Status parameter. The parameter should display OK or Not Run.
- If OK or Not Run is not displayed
Refer to Circuit/System Testing.
- If OK or Not Run is displayed
- If OK or Not Run is not displayed
- Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
- Verify the DTC does not set.
- If the DTC sets
Refer to Circuit/System Testing.
- If the DTC sets
- If the DTC sets
- All OK.