Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF.
- Disconnect the harness connector X2 at the K34 Glow Plug Control Module.
- Ignition ON.
- Verify that a test lamp illuminates between the Run/Crank Ignition 1 Voltage circuit terminal 33 and ground.
- If the test lamp does not illuminate
Repair the open or high resistance in the Run/Crank Ignition 1 Voltage circuit.
- If the test lamp illuminates
- If the test lamp does not illuminate
- Verify that a test lamp illuminates between the Run/Crank Ignition 1 Voltage circuit terminal 33 and the Signal Ground circuit terminal 10.
- If the test lamp does not illuminate
Repair the open or high resistance in the Signal Ground circuit.
- If the test lamp illuminates
- If the test lamp does not illuminate
- Replace the K34 Glow Plug Control Module.