- Ignition OFF, disconnect the harness connector at the B130 Exhaust Gas Recirculation Temperature Sensor.
- Verify the resistance between the signal terminal 1 and the low reference circuit terminal 2 is within the range specified in the Temperature Versus Resistance (EGT Sensors)
, Temperature Versus Resistance (EGR Temperature Sensors)
, Temperature Versus Resistance (Reductant Injector)
, Temperature Versus Resistance (Reductant Tank Temperature Sensor)
and Temperature Versus Resistance (Engine Coolant Temperature Sensor)
Table.NOTE: The J 25070 may be used to evaluate the sensor under high temperature conditions.
- If not within the range specified
Replace the B130 Exhaust Gas Recirculation Temperature Sensor.
- If within the range specified
- If not within the range specified
- Test for infinite resistance between each terminal and the sensor housing/case.
- If less than infinite resistance
Replace the B130 Exhaust Gas Recirculation Temperature Sensor.
- If infinite resistance
- If less than infinite resistance
- All OK