Circuit/System Verification
WARNING: This page is about a different variant/trim than selected.
- Ignition ON.
- Observe the Fuel Temperature Sensor parameter with a scan tool. The fuel temperature parameter should be within the operating range of -39 to 119°C (-38 to 246°F), depending on current ambient temperature and the vehicle operating conditions.
- If not within -39 to 119°C (-38 to 246°F)
Refer to Circuit/System Testing
- If within -39 to 119°C (-38 to 246°F)
- If not within -39 to 119°C (-38 to 246°F)
- Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
- Verify the DTC does not set.
- If the DTC sets
Refer to Circuit/System Testing
- If the DTC does not set
- If the DTC sets
- All OK.